
- Power Quality Analyzer - S Class
- Power Pole Fix
- IEC61000-4-30 S-Class, IEC61000-4-7 and IEC 61000-4-1 (Prodist Module 8)
- Flexible or Clamp-type Current Sensors
- Multifunction Energy Meter.
- RS-485/USB output and/or Bluetooth (Modbus-RTU).
- Aggregation Memory
- LCD Display
- Software and MMI (Man Machine Interface) Reading and Configuration
New

- Multifunction and Consumption Energy Meter
- Direct current measurement up to 63A or with Current Transformer.
- Mass Memory
- RS-485 (Modbus-RTU Protocol)
- Ethernet and/or Wi-Fi (Modbus-TCP/IP, MQTT or BACNet/IP Protocols)
- IoT and Industry 4.0 application
- Digital Input and Output
- Analog Input
- PT-100 Input (temperature)
- Software and MMI (Man Machine Interface) Reading and Configuration
- MMI (Man Machine Interface) Reading
New

- Multifunction and Consumption Energy Meter
- Mass Memory
- RS-485 (Modbus-RTU Protocol)
- LoRa (LoRaWAN or Private communication)
- Wi-Fi (Modbus-TCP/IP, MQTT or BACNet/IP Protocols)
- Bluetooth
- IoT and Industry 4.0 application
- Digital Input and Output
- Software and MMI (Man Machine Interface) Reading and Configuration
- MMI (Man Machine Interface) Reading
New

- Multifunction and Consumption Energy Meter
- Direct current measurement up to 120A or with Current Transformer.
- Mass Memory
- RS-485 (Modbus-RTU Protocol)
- LoRa (LoRaWAN or Private communication)
- Ethernet and/or Wi-Fi (Modbus-TCP/IP, MQTT or BACNet/IP Protocols)
- IoT and Industry 4.0 application
- Digital Input and Output
- Software and MMI (Man Machine Interface) Reading and Configuration
- MMI (Man Machine Interface) Reading
New

- Multifunction and Consumption Energy Meter
- Mass Memory
- RS-485 (Modbus-RTU Protocol)
- LoRa (LoRaWAN or Private communication)
- Wi-Fi and Ethernet (Modbus-TCP/IP, MQTT or BACNet/IP Protocols)
- Bluetooth
- IoT and Industry 4.0 application
- Digital Input and Output
- Software and MMI (Man Machine Interface) Reading and Configuration
- MMI (Man Machine Interface) Reading
New

- Multifunction and Consumption Energy Meter
- Mass Memory
- RS-485 (Modbus-RTU Protocol)
- LoRa (LoRaWAN or Private communication)
- Wi-Fi and Ethernet (Modbus-TCP/IP, MQTT or BACNet/IP Protocols)
- Bluetooth
- IoT and Industry 4.0 application
- Digital Input and Output
- Software and MMI (Man Machine Interface) Reading and Configuration
- MMI (Man Machine Interface) Reading

- Measurement + Protection
- Type: Window
- Primary Current: 200A -> 4,000A
- Window Dimension: 65x65, 78x78 or 105x105mm
- Window Diameter: 60, 70 or 90mm
- Product Dimensions: 206.5 x 215 x 70mm
- Measurement Accuracy Class: 0.3%, 0.6% or 1.2%
- Protection Class: of 10B20, 10B50 or 10B100
- Maximum Burden: 5, 12.5 or 25VA

- Measurement + Protection
- Type: Window
- Primary Current: 50A -> 5,000A
- Window Dimension: 65x65, 76x76 or 105x105mm
- Window Diameter: 65, 76 or 105mm
- Product Dimensions: 227 x 228 x 90mm
- Measurement Accuracy Class: 0.3%, 0.6% or 1.2%
- Protection Class: 10B10, 10B20, 10B50, 10B100 or 10B200
- Maximum Burden: 2.5, 5 12.5 or 25VA
New

- Online platform for energy management and submetering
- Real-time electrical measurements
- Automated Billing (for submetering) Generation
- Graph and Report Generation
- Measurement history
- Predicted consumption calculation
- Information for your management and energy efficiency actions.
- Easy and practical handling
New

- Multifunction and Consumption Energy Meter
- IoT and Industry 4.0 application
- Wi-Fi (Modbus-TCP/IP and MQTT), LoRa (LoRaWan) and RS-485 (Modbus-RTU).
- LoRa (LoRaWAN or private).
- Split-Core Current Transformer with RJ connection (Plug&Play)
- FRAM Memory
- Digital Inputs and Outputs.
- Software and APP for Reading and Configuration
- Versions with or without display

- Multifunction and Consumption Energy Meter
- Measurement Box
- Plug&Play
- Direct current measurement up to 120A or with Current Transformer.
- Mass Memory
- RS-485 (Modbus-RTU Protocol)
- Ethernet and/or Wi-Fi (Modbus-TCP/IP, MQTT or BACNet/IP Protocols)
- IoT and Industry 4.0 application
- Digital Input and Output
- Analog Input
- PT-100 Input (temperature)
- Software Reading and Configuration
- MMI (Man Machine Interface) Reading

- Power Quality Analyzer - S Class
- Portable
- IEC61000-4-30 S-Class, IEC61000-4-7 and IEC 61000-4-1 (Prodist Module 8)
- Flexible or Clamp-type Current Sensors
- Multifunction Energy Meter.
- RS-485/USB output and/or Bluetooth (Modbus-RTU).
- Aggregation Memory
- LCD Display
- Software and MMI (Man Machine Interface) Reading and Configuration
New

- Power Quality Analyzer - S Class
- IEC61000-4-30 S-Class, IEC61000-4-7 and IEC 61000-4-1 (Prodist Module 8)
- Multifunction Energy Meter.
- RS-485 output and/or Bluetooth (Modbus-RTU).
- Ethernet output (Modbus-TCP/IP).
- Aggregation Memory
- LCD Display
- Software and MMI (Man Machine Interface) Reading and Configuration